The SecureLinx SLC secure console servers provide secure, remote access to servers and IT infrastructure equipment, whether it’s located down the hall or across the globe. IT professionals can use SecureLinx SLC to monitor, manage and troubleshoot nearly anything in the data center rack, from anywhere, at any time – even if servers or networks are down. This capability means faster response rates which translate into reduced costs and less downtime.
With a common GUI interface that is simple to set up and use, SecureLinx SLC serial console server provides easy, secure administration and management of IT equipment – from anywhere, at any time.
Through our secure console server, system administrators can securely access and control a wide variety of IT and data center equipment, including Linux, Unix or Windows 2003 servers, routers, switches, PBXs, UPSs, and even building access devices through their serial ports. Connecting from eight to 48 serial ports to an SLC provides the ability to centrally monitor, manage and troubleshoot many pieces of equipment using familiar tools such as Telnet or SSH.
Anytime, Anywhere Solution
With SecureLinx, it’s just like being there. Access to the SLC device ports is accomplished via Telnet/SSH or, a web page launched console client, with no proprietary software required. Any server or IT asset that provides console or serial port management services can be managed remotely from any location with the same interface and capabilities available locally. The command line interfaces of most IT equipment provide low-level access for reconfiguring, rebooting, and even reloading firmware. SLC enables IT managers to take advantage of these functions from a single point-of-contact over a network or out-of-band dial-up connection. In-band access is available through dual Ethernet connections for both public and management networks.
Integrated Security
Protecting IT resources is a top priority. SecureLinx SLC provides security features such as SSL and SSH for data encryption. It also supports remote authentication for integration with other systems already in place in the data center. For added protection, the SLC also includes firewall features to reject connection attempts or block ports and is the first console server with a NIST-certified AES encryption.
Easy to Deploy and Use
SecureLinx SLC provides a comprehensive suite of features enabling quick setup and deployment, with typical “box to operation” times of fewer than 10 minutes. A front panel LCD with keypad, “Quick Setup” web interface and a command line interface (CLI) setup script are all available. The comprehensive online help system includes context-sensitive information during configuration and operation. SecureLinx SLC offers single or dual AC or dual DC power supply options. Other key features include SNMP support and e-mail notifications with string recognition and RegExp support.
SecureLinx SLC is also NEBS Level 3 compliant, the most stringent of the three levels of conformance. A de facto standard in the telecommunication industry, NEBS (Network Equipment Building Systems) ensures continuous, redundant operation of products meeting strict physical, electrical and environmental requirements for safe and reliable operation within carrier infrastructures.
Order Information & Part Numbers
Lantronix products are available from a wide variety of leading technology vendors.
Click here to use our Partner Locator.
To speak with a Lantronix sales representative in North America, call +1 (800) 422-7055. For a full listing of Lantronix worldwide offices, please see our Contact Information page.
Part Number Description SLC00812N-02 SLC8: 8 Port, Single AC Supply Secure Console Manager
RoHS SLC00822N-02 SLC8: 8 Port, Dual AC Supply Secure Console Manager
RoHS SLC00824T-02 SLC8: 8 Port, Dual DC Supply Secure Console Manager, NEBS
RoHS SLC01612N-02 SLC16: 16 Port, Single AC Supply Secure Console Manager
RoHS SLC01622N-02 SLC16: 16 Port, Dual AC Supply Secure Console Manager
RoHS SLC01624T-02 SLC16: 16 Port, Dual DC Supply Secure Console Manager, NEBS
RoHS SLC03212N-02 SLC32: 32 Port, Single AC Supply Secure Console Manager
RoHS SLC03222N-02 SLC32: 32 Port, Dual AC Supply Secure Console Manager
RoHS SLC03224T-02 SLC32: 32 Port, Dual DC Supply Secure Console Manager, NEBS
RoHS SLC04812N-02 SLC48: 48 Port, Single AC Supply Secure Console Manager
RoHS SLC04822N-02 SLC48: 48 Port, Dual AC Supply Secure Console Manager
RoHS SLC04824T-02 SLC48: 48 Port, Dual DC Supply Secure Console Manager, NEBS
RoHS Optional Cables/Adapters 200.2066A RJ45 to DB25M Cable Adapter
200.2067A RJ45 to DB25F Cable Adapter
200.2069A RJ45 to DB9M Cable Adapter
200.2070A RJ45 to DB9F Cable Adapter
ADP010104-01 Cable; rolled serial adapter, 0.1m (0.33 ft) 500-137 Cable; rolled serial, RJ45 to RJ45, 3m (9.8 ft.)
500-153 Cable; Loopback 56KMODEMCARD-02 PC Card V.92 Modem, RoHS SupportLinx Extended Support
Lantronix provides extended support and warranty options for this product. Click here for more information. Extended support options are available for the following products:

Extended
Warranty Advance
Replacement 24x7 Support
EDS8/16/32
SLC08/16/32/48
SLK1/08/16
SLPH08
SLPV16 
Features & Specifications
Accessibility In-Band (Ethernet) - dual Ethernet portsOut-of-Band (local terminal or modem)
Security and Authentication Secure Shell (SSH v1, v2, Public Key)Packet filtering (firewall)Per port user permissionsCentrally Managed port permissions (via NIS)Remote authentication: LDAP, NIS, RADIUS, Kerberos, TACACS+
Port Access Telnet/SSH to SLC command lineTelnet/SSH/raw-TCP direct to IP address and port numberWeb Telnet/SSHMultiple concurrent Telnet/SSH sessions (64 max)Simultaneous access on the same port (listen mode)No inadvertent "breaks" – Sun break-safeCustomizable multi-level user menusPC card modem accessAutomatic port-initiated connections to network host or neighboring portEnable terminal login on any device port
Data Capture and Notification Port buffering – 256 KB per portPort logging to local files, PC card Ext2 & Fat/Fat32, remote NFS files (simultaneous)Local logging viewable via CIFSSystem event logsConsole event notification (e-mail)Event string recognition (RegExp)
Management Front panel keypad/display for network setupQuick setup and configuration web interface (SSL)CLI setup scriptCommand line interface (Telnet, SSH, web telnet/SSH or direct serial)SNMP (MIB II) compatible - v1, v2, v3, custom MIB'sIntegrated power management support (SLP)Diagnostics and port status countersPerformance monitoring utilityPacket generation utilityNetwork trace utilityLocal subnet search for other SLCs
Additional Protocols Supported DHCP and BOOTP for dynamic IP address assignmentNTP for time synchronizationFTP, TFTP, SFTP, SCP client for file transfersDNS for text-to-IP address name resolutionSSH, SSL, Telnet, TCP & UDP, PPP w/PAP/CHAP, NFS and CIFS for connections in and out of the SLCRIP and RIPv2
Interfaces Network Two 10Base-T/100Base-TX RJ45 Ethernet
Devices 8, 16, 32, or 48 RS-232 (RJ45), 300 to 115,200 bps
Console RS-232 (RJ45), 300 to 115,200 bps
PC Card Interface Two 32-bit CardBus PC Card slots
Operating System Embedded Linux
Power Requirements AC Input (single or dual) 100-240VAC, 50 to 60 Hz IEC-type cord
DC Input -24 to -60 VDC
Power Consumption Less than 20W maximum
Environmental Operating 0° to 50°C (32° to 122°F), 30 to 90%RH, non-condensing
Storage -20° to 70°C (-4° to 158°F), 10 to 90%RH, non-condensing
Heat Flow Rate 68 BTU per hour
Physical Dimensions (HxWxD) 1U, 1.75 x 17.25 x 12 in.
Weight 10 lbs. maximum, depending on options
Shipping Weight 14 lbs. maximum
Certification FCC Part 15, CE (EN55022, EN55024, EN60950), CSA, VCCI, TÜV Rheinland, GS Mark, UL/CUL, C-Tick, CB Scheme, NIST-certified implementation of AES (Advanced Encryption Standards) as specified by FIPS-197, NEBS Level 3 (DC models only)
It is highly recommended to always use the most recent driver version available.
Do not forget to check with our site as often as possible in order to stay updated on the latest drivers, software and games.
Try to set a system restore point before installing a device driver. This will help if you installed a wrong driver. Problems can arise when your hardware device is too old or not supported any longer.
Примечание: Ссылка "скачать" может вести как непосредственно на файл, так и на сайт производителя, на котором Вы можете найти нужный файл.
Это связано с тем, что некоторые производители не позволяют размещать прямые ссылки на файлы.