Intel S2600CO Server Board EFI Firmware 01.03.0002

Versions: - BIOS : 01.03.0002 - ME : 02.01.05.107 - BMC : 1.10.3560 - FRUSDR : 1.08 BIOS changes in release 01.03.0002: - Fixed: NIC Information can not be saved in the Sysinfo log file and it cannot be retrieved or set using the syscfg utility. - Fixed: If Remotely redirecting an ISO image from a client and the target system is restarted, the target system will automatically boot to the redirected ISO image and start an OS installation. ME Changes in release 02.01.05.107: - Fixed: FW may hang in initialization state after the update of entire ME region is interrupted by AC loss. - Fixed: FW may become unresponsive after switching from Recovery to Operational (e.g. during Direct Update). - Global Reset or Power Button Override can’t get ME out of the error condition. BMC Changes in release 1.10.3560: - Fixed: Updated FRUSDR files: S2400BB to version 0.09, S2600CP to version 1.06, S2600CO to version 1.07, W2600CR to version 1.07, S2400EP to version 1.00, S2600IP to version 1.07, S2600JF to version 1.07, S2400LP to version 1.06, S2600CP to version 1.07, S2600CO to version 1.08, W2600CR/S2600IP to version 1.08, S2400GP to version 1.05, S1600JP to version 0.05, S2600JF to version 1.08, S4600LH to version 0.12, S2600WP to version 1.05, S2600GZ/S2600GL to version 1.03 - Fixed: Adjust RGMII Tx clock delay to -250ps for S1400SP according to SI requirement - Fixed: Command OEM Get Reading. will now return units-based value converted by using .y=Mx+B - Fixed: Fixes to LCD Code defects identified in code review were incorporated - Fixed: Some strings on LCD were formerly displayed improperly on LCD - Fixed: Increased total SDR record length to 0x48h from 0x40h to accommodate the S4600LH SDR requirements - Fixed: S1600JP: Corrects the baseboard temperature sensor mapping so that it works - Fixed: After forcing a CATERR on S4600LH, the debug information from Embedded Web Server lacks some information - Fixed: LAN channel cannot get DHCP IPv4 address after disabling VLAN on it - Fixed: NMI sensor event isn't logged after issuing "chassis control" command to trigger NMI - Fixed: SUT hang at POSTCODE: 0x63 while BMC LAN connected to a switch loop environment - BMC would freeze under heavy network traffic loads (e.g. broadcast storm) - Fixed: S4600LH: Fan speed reading not correct - Added other chassis support in S4600LH and corrected RPM calc - Also updated S1400FP/S1400SP SDR to reflect change. - Fixed: Network Interface hold time was out of spec for S2600GZ/S2600GL and S2400BB - Fixed: Issuing incorrect "Set CR Configuration" command returns wrong error code - Fixed: LCP error messages are not scrolling automatically without pressing LEFT and RIGHT keys - Fixed: LCP default banner text when server with normal health is displaying some junk characters at the end - Fixed: Number of characters displaying in LCP display is only 16 but it should be 18 characters - Fixed: LCP displays "No BIOS POST C" when enter into LPC under VIEW menu - Fixed: Unable to view the entire IP or Gateway or Subnet addresses using LCP display, last digit is missing during display. - Fixed: Firmware information contents in LCP displaying does not match the actual version - Fixed: Banner text is not reflecting correct information after selecting SM, LPC, or POW as a banner - Fixed: LCP default screen after power on is not the correct banner text - Fixed: S2400SC shows no socket present in CPU information page of Embedded Web Server - SMBIOS rev 2.7.1 added additional socket types. This change adds those types to the SMBIOS translation tables. - Fixed: Updated S4600LH SDR to resolve issues where fans specified in FCT SDRs couldn't be controlled with fan domains. - Fixed: BMC 1.08 S4600LH SDR was missing Sensor 0x2C (Riser 2 Left Forward Temperature) - Fixed: Exit Air Temp reading mismatch when using IPMI command under Linux - The sensor initialization code was checking both assertion and deassertion enables and settable/readable thresholds before actually setting the thresholds. This was causing the Exit Air Temp sensor to fail to set thresholds (all thresholds became 0) - Fixed: Host name is not included in Email Alert subject line - Subject line could potentially be set before host name was set. This change sets the subject line again after the host name is changed - Fixed: BMC FW must satisfy open source advertising clause for OpenSSL - Added "About" button to top bar to satisfy item 6 in the OpenSSL license. - Added: Changed SDR of S2600CP, S2600CO, W2600CR/S2600IP, and S2400GP to add Dynamic Power Unit Redundancy Sensors - Added: Add S1600JP and S2600WP PCIeSlotMap Table - Added: Adds option (0xfe) for SlotIPMB command to ignore mux completely FRUSDR Changes in release 1.08: - Change 'Pwr Unit Redund' sensor(0x02) rearm type to manual rearm. - Update FRUSDR utility to version 11 build 11. - Modify Global Clamp Header 0x2F Sensor reading unavailable Control Value. - Follow Copper Pass FSC config sheet Rev (2.9).

  • Разработчик: Intel
  • ОС: OS Independent
  • Размер: 36.9 MB
Скачать