BIOS changes in 01.08.0003: - Added C0 microcode version 0x405 for Intel Xeon processor E5-4600/2600/2400 v2. NOTE: - This BIOS does not support Intel Xeon processor E5-4600/2600/2400 v2 steppings earlier than C0. ME changes in 02.01.07.112: - Fixed: ME may fail to perform reset initiated with IPMI command (02h Cold Reset or DFh Force ME Recovery) - observed after few hundreds of successful resets. - Fixed: CPU Memory Throttling Status Sensor gets latched in "upper non recoverable" state following Memory Throttling event after G3. BMC Changes in 01.17.4151: - Fixed: S4600LH: Updated to FRUSDR 19 package - Fixed: S2600JF: Updated to FRUSDR 1.10 package - Fixed: S2400SC: Updated to FRUSDR 1.08 package - Fixed: S2400EP: Updated to FRUSDR 1.01 package - Fixed: S1400FP: Updated to FRUSDR 1.01 package - Fixed: S2600WP: Updated to FRUSDR 1.07 package - Fixed: S2400BB: Updated to FRUSDR 1.02 package - Fixed: S1600JP: Updated to FRUSDR 1.00 package - Fixed: Fixed typo in uboot code for S1400FP - Fixed: VFP power led always solid green while system into S1 state. - Fixed: FW versions retrieved by IHC are incorrect. - Fixed: PSU Config Error deassert event not in SEL after removal of incorrect power supply. - Fixed: Fix a DIMM Thrm Mgn error in SEL while load BIOS EPSD default - Fixed: Embedded Web Server SEL logs, added "OS Event" as the sensor name for events generated by 0x0041, to resolve incorrect sensor name & type of SEL after Windows 2008 R2* 64bit graceful shutdown - Fixed: Remove the option of selecting IPv6 address from LCP. - Fixed: Some special characters show incorrectly on the LCP - Fixed: The last BIOS POST code on the LCD panel doesn't match with the boards POST CODE LED. - Fixed: Failed to test PEF Bit for Get PEF Capabilities. - Fixed: LCP displays "No BIOS POST C" when enter into LPC under VIEW menu. - Fixed: Connecting LCP to faulty system (system which keeps logging events) then LCP is unusable. - Fixed: Multiple KVM socket error and media redirection errors - Fixed: Embedded Web Server - JViewer "Error opening video socket" (Console Redirection Fails) - Fixed: Web Console Remote Session check. - Fixed: BMC FW versions displayed by LCP are incorrect - Fixed: SOL session started in SMASH session times out after 5 minutes - Fixed: SSH SMASH session does not allow settings1/timeout value greater than 600 seconds. - Fixed: LCP Configuration LAN Subnet Mask shortened name incorrect. - Fixed: VBAT voltage is low from BMC sensor reporting. - Fixed: PEF Postpone timer test failing - Fixed: S4600LH: LCP displays incorrect Server Name - Fixed: LCP: Active event is displayed incorrectly - Fixed: LCP custom string not replacing the banner - Fixed: Embedded Web console not displaying sensor values for sensors from another controller - Fixed: IPv6 is not supported on LCP, but the "Conf" screen showed an option to configure IPv6 address. - Fixed: Update PSSF162202A firmware - Bootloader changes - CRC 16 changes to fix firmware update failure issue. - Fix for READ_EIN and READ_PIN calculation - Fix includes Embedded Web Server reporting 0 W, double Power value workaround for ME issue. - Fixed: S4600LH: Change maximum link speed of RMM4 Dedicated NIC to 100Mbps - Fixed: The current scrolling functionality of the LCP forcing the user to wait till the scrolling of the existing text completes though the, or user is not interested in reading the entire text. - Fixed:Fix wrong slot number mapping for S2600GZ/S2600GL. Slot numbers were reversed. - Fixed: 1200 W 02 F PSU FW file name was specified in hex instead of decimal. - Fixed: S4600LH: LAN sku, doesn't have Power button. - BMC shouldn't support "stayoff" option in power restore policy. - Restore policy should be POWERON by default. - Fixed: S2600JF and S2600WP: IO Mod Presence shows not present when SAS Module is present. - Fixed: Power Unit Redundancy sensor did not behave as expected. - The Power Unit Redundancy sensor was not getting rearmed when AC/DC Input power was removed and then restored. - When interrupting input power from one of the redundant power supplies, the Status LED will blink green. - Restoring power to the power supply causes the Status LED to return to solid green and there is a SEL entry for Redundancy regained. - Fixed: Scale CFM sensor reading by B value in SDR. - Platforms are using different scaling factors in the SDR for the system CFM sensor. This change reads the scaling factor from the SDR and adjusts the raw sensor reading accordingly. - Fixed: When a Power Supply was inserted, the PS Redundancy sensor was not getting rearmed. - The PS Redundancy sensor is rearmed when a PS is inserted and full redundancy is regained. - When redundancy is regained, the LED should stop blinking and turn solid green. - There should also be a Redundancy Regained SEL event logged. - Added: Add auto detection, sensor, and Fan Speed Control support for Intel Xeon Phi Coprocessor adapters - Added: Added additional product ID for Intel Xeon Phi Coprocessor - Added: Disable POST codes LED output after system has completed POST FRUSDR Changes in release 1.09: - Update some temperature sensor's normal value and threshold refer to config-table 3.6 - Update the data record of sensor "Exit Air" - Update the system airflow formula record for R23XX chassis Versions: - System BIOS - 01.08.0003 - ME Firmware - 02.01.07.112 - BMC Firmware - 01.17.4151 - FRUSDR - 1.09
Скачать